Siemens Robicon A1A10000432.30MControl board

Siemens Robicon A1A10000432.30MControl board

Siemens Robicon Control board

Origin: Germany


Brand: Siemens


The Siemens A1A10000432.30M control board is a key component in Siemens high-voltage frequency converters, mainly used to receive signals from the main control system, provide control signals to the drive board, perform real-time fault monitoring, report fault information to the main control system, and finally supply power to the control board itself.


0.00
0.00
  

Siemens Robicon Control board

Origin: Germany


Brand: Siemens


The Siemens A1A10000432.30M control board is a key component in Siemens high-voltage frequency converters, mainly used to receive signals from the main control system, provide control signals to the drive board, perform real-time fault monitoring, report fault information to the main control system, and finally supply power to the control board itself.


Product Introduction

Receiving signals from the main control system: The A1A10000432.30M control board receives signals from the main control system and provides control signals to the drive board.


Real time fault monitoring: This control board performs real-time fault monitoring and reports fault information to the main control system to ensure the stable operation of the system.


Power supply function: Provide power to the drive board to ensure the normal operation of the system.


Interface and connection method


Fiber optic interface: communicates with the main control system.


24V power input interface: connected to the power unit power board.


Drive signal interface: connected to the drive board to provide control signals.


15V power output interface: supplies power to the driver board.


Overvoltage and undervoltage detection interface: connected to the positive and negative busbars of the unit.


Phase loss detection interface: connected to fuse auxiliary switch.


Overheating detection interface: connected to temperature detection switch.


Power on thyristor drive signal interface: Connect to the thyristor gate.


Bypass thyristor drive signal interface: connected to the bypass thyristor gate.


Bypass OK signal detection interface: connected to the bypass OK board


Many products have not been listed yet. Please contact us for more products If there is any

inconsistency between the product modeland the displayedpicture,the model shall prevail.

Please contact us for specific product pictures, and we will arrange for photos to be taken in the warehouse for confirmation

Technical Team Service Hotline:0591-85299001